KLIK : KSKV
KLIK : https://docs.google.com/document/d/19UYOqkTPAq3IF1x4CM-xGrOTbSNuQLBt/edit
MINISTRY
OF EDUCATION, MALAYSIA
VOCATIONAL
COLLEGE STANDARD CURRICULUM
PROGRAMME
|
:
|
ELECTRICAL TECHNOLOGY
|
||
COURSE
NAME
|
:
|
SINGLE
PHASE DRAWING
|
||
CODE
NAME
|
:
|
ETE
1013
|
||
LEVEL
/ SEMESTER
|
:
|
2
SEMESTER 1
|
||
CREDIT
UNIT
|
:
|
3.0
|
||
CONTACT
HOUR
|
:
|
FACE
TO FACE
|
:
|
5.0
HOURS / WEEK
|
NON
FACE TO FACE
|
:
|
|||
COURSE
TYPE
|
:
|
VOCATIONAL
|
||
PREREQUISITE
|
:
|
-
|
||
CORE
REQUISITE
|
:
|
-
|
COURSE OUTCOMES (COMPETENCY UNIT WORK ACTIVITIES)
At the end of the course, students should be able to:-
- Identify single phase drawing specifications and requirement.
- Carry out layout drawing.
- Carry out single line / schematic diagram drawing.
- Carry out single phase wiring drawing.
- Inspect single phase drawing.
COURSE DESCRIPTION (COMPETENCY UNIT DESCRIPTOR)
Single phase drawing is covering the scope of
competency to carry out wiring activities for Single Phase based on drawing
given by utilizing wiring tools, equipment and materials in compliance with
Electrical Act 1990, Electrical Regulation 1994 and other related rules and regulations
body and statutory requirements. The personnel who are competent in the single
phase electrical drawing must be able to identify drawing specification for
single phase wiring and carry out drawing according to standard requirements.
CONTENT
AND LEARNING STANDARDS
PROGRAMME
|
:
|
ELECTRICAL TECHNOLOGY
|
COURSE
NAME
|
:
|
SINGLE
PHASE DRAWING
|
CODE
NAME
|
:
|
ETE 1013
|
CONTACT HOURS
(TRAINING DURATION)
|
CONTENT STANDARD
(WORK ACTIVITIES)
|
LEARNING
STANDARD
(RELATED KNOWLEDGE / APPLIED SKILLS
/
ATTITUDE / SAFETY / ENVIRONMENTAL)
|
PERFORMANCE CRITERIA /
ASSESSMENT CRITERIA
|
20 HOURS
(4 WEEKS)
THEORY :
8 HOURS
PRACTICAL :
12
HOURS
|
1. IDENTIFY SINGLE PHASE DRAWING SPECIFICATIONS AND REQUIREMENT
|
RELATED
KNOWLEDGE
1.1 Procedure of site visit and evaluation.
1.2 Technique to produce layout drawing.
1.3 Calculation of Ohm’s Law.
1.4 Calculation of diversity factor.
1.5 Bill of quantity (BQ).
1.6 Types of calculation: Total connected load (TCL) and
Maximum Demand (MD).
1.7 Diversity factor.
1.8 Various type of conductor: Copper and Aluminium.
1.9 Various type of cable, such as: XLPE/SCT/PVC,
PVC/PVC, PVC/SWA/PVC and XLPE/SWA/PVC.
1.10 Various types of protection devices: MCB, MCCB,
RCCB/ELCB and Fuse.
1.11 Types of single phase wiring: Surface wiring,
Conceal wiring, Conduit wiring, Conceal conduit Wiring, Ducting wiring,
Trunking/Casing, Cable tray and Underground.
1.12 Earthing / grounding requirement.
1.13 Electrical Act & Regulation and Standard: Energy
Commission Act 2001, Electricity Supply Act 1990 (Act 447), Electrical Regulation
1994, MS 1936: 2006 / IEC 60364, MS 1979: 2007 (COP) Electrical Installation
of Buildings – Code of practice (COP) and Based on latest instruction by
regulatory body.
1.14 Occupational Safety & Health Act 514 (OSHA)
1994.
1.15 Authorisation requirement to access site such as:
Green card and Safety passport
RELATED
SKILLS
1.1 Determine procedure to carry out site visit and
evaluation.
1.2 Visit and evaluate site location.
1.3 Sketch layout plan.
1.4 Calculate Ohm’s Law
1.5 Calculate total connected load.
1.6 Calculate maximum demand.
1.7 Determine types of single phase wiring.
1.8 Determine types of protection devices.
1.9 Determine types of conductor.
1.10 Determine types of cable.
1.11 Determine Authorisation requirement to access site.
ATTITUDE
/ SAFETY / ENVIRONMENTAL
Attitude
1.1 Meticulous in calculating Ohm’s Law, TCL
& MD.
1.2 Adhere to safety regulation.
|
ASSESSMENT CRITERIA
1.1 Sketch layout plan according to
requirement.
1.2 Calculate Ohm’s Law, MD & TCL
correctly according to Electrical Act & Regulation and Standard.
1.3 List out the selection of protection
devices, and cable listed out according to Electrical Act & Regulation
and Standard.
|
CONTENT
AND LEARNING STANDARDS
PROGRAMME
|
:
|
ELECTRICAL TECHNOLOGY
|
COURSE
NAME
|
:
|
SINGLE
PHASE DRAWING
|
CODE
NAME
|
:
|
ETE 1013
|
CONTACT HOURS
(TRAINING DURATION)
|
CONTENT STANDARD
(WORK ACTIVITIES)
|
LEARNING
STANDARD
(RELATED KNOWLEDGE / APPLIED SKILLS
/
ATTITUDE / SAFETY / ENVIRONMENTAL)
|
PERFORMANCE CRITERIA /
ASSESSMENT CRITERIA
|
35 HOURS
(7 WEEKS)
THEORY :
14 HOURS
PRACTICAL :
21
HOURS
|
2.
CARRY OUT LAYOUT
DRAWING
|
RELATED
KNOWLEDGE
2.1 Drawing set.
2.2 Computer Added Drawing software.
2.3
Computer
operation.
2.4
Measurement
scale technique.
2.5
Building
layout symbol.
2.6
Application
of configuration.
2.7
Electrical
symbol, circuit and measurements for layout drawing.
2.8
Electrical
accessories and fittings.
2.9
Procedure to
draw layout drawing.
2.10
Format of
layout drawing.
RELATED
SKILLS
2.1 Acquire drawing set.
2.2 Utilise Computer Added Drawing.
2.3 Utilise computer system.
2.4 Utilise drawing software.
2.5 Interpret building layout plan.
2.6 Determine electrical symbol.
2.7 Determine electrical accessories/fittings.
2.8 Sketch building layout.
2.9 Determine single phase wiring configuration.
2.10 Determine types of accessories and fittings to be
used.
2.11 Draw building layout (indoor / outdoor).
ATTITUDE
/ SAFETY / ENVIRONMENTAL
Attitude
2.1
Handle
computer with care.
|
ASSESSMENT CRITERIA
2.1 Sketch building layout according to
specification.
2.2 Determine the single phase wiring
configuration according to specification.
2.3 Determine the types of accessories and
fittings accoding to requirement and specification.
2.4 Carry out layout drawing drew according
to requirement and specification.
2.5 Check layout drawing format according to
standard format.
|
CONTENT
AND LEARNING STANDARDS
PROGRAMME
|
:
|
ELECTRICAL TECHNOLOGY
|
COURSE
NAME
|
:
|
SINGLE
PHASE DRAWING
|
CODE
NAME
|
:
|
ETE 1013
|
CONTACT HOURS
(TRAINING DURATION)
|
CONTENT STANDARD
(WORK ACTIVITIES)
|
LEARNING
STANDARD
(RELATED KNOWLEDGE / APPLIED SKILLS
/
ATTITUDE / SAFETY / ENVIRONMENTAL)
|
PERFORMANCE CRITERIA /
ASSESSMENT CRITERIA
|
25 HOURS
(5 WEEKS)
THEORY :
10 HOURS
PRACTICAL :
15
HOURS
|
3.
CARRY OUT SINGLE LINE
/ SCHEMATIC DIAGRAM DRAWING
|
RELATED
KNOWLEDGE
3.1 Single line/schematic diagram drawing requirements
and specifications as per rules and regulation.
3.2 Devices and cable specification: Switches,
Protection, Cable and Socket outlet (Switch / Unswitch).
3.3 Circuit connection method.
3.4 Types of single phase wiring: Indoor single phase
wiring and Outdoor single phase wiring.
3.5 Electrical symbol circuit.
3.6 Procedure to draw single line drawing.
3.7 Format of single line drawing
RELATED
SKILLS
3.1 Determine electrical symbol.
3.2 Determine electrical accessories and fittings.
3.3 Read and interpret blue print.
3.4 Determine types of single phase wiring protection.
3.5 Determine types of accessories and fittings.
3.6 Compare single line drawing to layout drawing.
3.7 Draw electrical single line drawing.
ATTITUDE
/ SAFETY / ENVIRONMENTAL
Attitude
3.1 Handle computer with care.
3.2 Adhere to ergonomic requirements.
|
ASSESSMENT CRITERIA
3.1 Determine single line drawing requirements
and specification according to standard format.
3.2 Determine the devices and cable
specification according to Electrical Act & Regulation and Standard.
3.3 Determine electrical symbol circuit
according to requirement and specification.
3.4 Draw single line drawing drew according
to requirement and specification.
3.5 Check single line drawing format according
to standard format.
|
CONTENT
AND LEARNING STANDARDS
PROGRAMME
|
:
|
ELECTRICAL TECHNOLOGY
|
COURSE
NAME
|
:
|
SINGLE
PHASE DRAWING
|
CODE
NAME
|
:
|
ETE 1013
|
CONTACT HOURS
(TRAINING DURATION)
|
CONTENT STANDARD
(WORK ACTIVITIES)
|
LEARNING
STANDARD
(RELATED KNOWLEDGE / APPLIED SKILLS
/
ATTITUDE / SAFETY / ENVIRONMENTAL)
|
PERFORMANCE CRITERIA /
ASSESSMENT CRITERIA
|
15 HOURS
(3 WEEKS)
THEORY :
6 HOURS
PRACTICAL :
9
HOURS
|
4.
CARRY OUT SINGLE PHASE
WIRING DRAWING
|
RELATED
KNOWLEDGE
4.1 Type of accessories.
4.2 Single phase wiring connection, terms and specification.
4.3 Single phase wiring protection.
4.4 Earthing system layout.
4.5 Cable size chart.
4.6 Single phase wiring specification and regulation.
4.7 Procedure to draw single phase wiring drawing.
4.8 Format of single phase wiring drawing
RELATED
SKILLS
4.1 Read and interpret blue print.
4.2 Determine types of electrical connection.
4.3 Differentiate type of loads.
4.4 Determine types of connection.
4.5 Determine type of single phase wiring/ accessories
and fittings.
4.6 Draw single phase wiring drawing.
ATTITUDE
/ SAFETY / ENVIRONMENTAL
Attitude
4.1 Meticulous in drawing.
|
ASSESSMENT CRITERIA
4.1 Determine Single phase wiring
configuration according to requirement and specification.
4.2 Determine the types of accessories and
fittings according to requirement and specification.
4.3 Draw single phase single phase wiring
drawing according to requirement and specification.
4.4 Check single phase single phase wiring
drawing format according to standard format.
|
CONTENT
AND LEARNING STANDARDS
PROGRAMME
|
:
|
ELECTRICAL TECHNOLOGY
|
COURSE
NAME
|
:
|
SINGLE
PHASE DRAWING
|
CODE
NAME
|
:
|
ETE 1013
|
CONTACT HOURS
(TRAINING DURATION)
|
CONTENT STANDARD
(WORK ACTIVITIES)
|
LEARNING
STANDARD
(RELATED KNOWLEDGE / APPLIED SKILLS
/
ATTITUDE / SAFETY / ENVIRONMENTAL)
|
PERFORMANCE CRITERIA /
ASSESSMENT CRITERIA
|
5 HOURS
(1 WEEKS)
THEORY :
2 HOURS
PRACTICAL :
3
HOURS
|
5.
INSPECT SINGLE PHASE
DRAWING
|
RELATED
KNOWLEDGE
5.1 Types of drawing.
5.2 Procedure to check drawing error.
5.3 Drawing specification.
5.4 Procedure to check Ohm’s Law, Total Connected Load
(TCL) and Maximum Demand (MD) from drawing.
5.5 Tender/clients requirements.
5.6 Procedure to submit single phase wiring drawing for
approval.
RELATED
SKILLS
5.1
Determine
types of drawing.
5.2
Check
drawing error.
5.3
Check
drawing specification against design requirements.
5.4
Calculate Ohm’s
Law, TCL & MD.
5.5
Print out
single phase drawing.
5.6
Determine
tender / clients requirements.
5.7
Submit
single phase wiring drawing for approval to superior.
5.8
Carry out
housekeeping activities.
ATTITUDE
/ SAFETY / ENVIRONMENTAL
Attitude
5.1
Meticulous in calculation.
|
ASSESSMENT CRITERIA
5.1
Check
the drawing error correctly according to specification.
5.2
Check
drawing specification according to format.
5.3
Calculate
Ohm’s Law, TCL & MD according to Electrical Act & Regulation and
Standard.
|
CORE ABILITY
CORE ABILITY
|
SILA RUJUK LAMPIRAN A : JADUAL PEMETAAN NOSS
DAN KSKV
SILA RUJUK LAMPIRAN B : JADUAL PEMETAAN NOSS
DAN CORE ABILITY
|
TOOLS, EQUIPMENT AND MATERIALS (TEM)
ITEMS
|
RATIO
(TEM : TRAINEES)
|
1.
Schematic diagram
2.
Block Diagram
3.
Measuring Instruments
4.
Electrical components/Parts Specification
5.
Equipment Data Book
6.
Drawing instrument
7.
Computer
8.
Computer Added Drawing software
|
1
: 1
1
: 1
1
: 1
1
: 1
1
: 2
1 : 1
1 : 1
1 : 5
|
REFERENCES
|
1. Undang-Undang
Malaysia. 2005. Akta
Bekalan Elektrik 1990 dan Peraturan-Peraturan Elektrik 1994, Pindaan sehingga
2005. MDC Publisher Sdn Bhd Malaysia.
2. Suruhanjaya
Tenaga Malaysia. Standard Pendawaian
Malaysia (Electrical Installations Of Buildings - MS IEC 60364) Jabatan
Standard Malaysia
3. The Institution of Electrical Engineers, 1998,
Peraturan-Peraturan bagi Pemasangan Elektrik, Edisi 16. Golden Books Centre Sdn Bhd
4. Giesecke,
F. E. et. Al. 2002. Technical Drawing. Prentice
Hall
5. BS 7671: 2001 Requirements for Electrical Installations
(IEE Wiring Regulations, Sixteenth Edition) Institution of Electrical
Engineers
|